Ignition Control Systems

 


MPI Control Systems utilize the latest microprocessor based designs to provide improved programming and diagnostics for today's industrial gas engines.

Operators of MPI controllers have more information to be used locally or remotely, giving them "full authority" to fine tune their operations for enhanced efficiency.

 

 

FEATURES

16-bit and 32-bit microprocessor controllers
Five Timing Reference Options including Camless Operation
Remote PLC engine management system or cellular communication
Field-programmable from front panels
Run-time diagnostics and prognostics
Two field-adjustable timing schedules
4-line window display (local or remote)
True Primary and Secondary Diagnostics
Highly accurate and stable timing (±0.25°)
Two analog inputs for remote timing control

 

BENEFITS

Increased spark life
Equalizes cylinder output
Less RPM variations
Reduces unscheduled downtime
User friendly: no chips to change or remove
No PC or handheld programmer required
Easier operation

 

SPECIFICATIONS

Power Requirements:
MPI-16/8: 18-32 Volts (24 VDC nominal) 3.0 Amps max.
Note: The input current is dependent on firing rate.
MPI-32:
18-32 Volts, 6.0 Amps max.

Temperature: Operating Range : –20° , +70° C.

CSA Certified for Class I, Div 2, Groups B, C, D
MPI-16: Fires 16 outputs, no simultaneous pairing.
MPI-8:
Fires 8 outputs, no simultaneous pairing.
MPI-32:
Fires 32 outputs, 2 outputs can fire simultaneously.

Energy Storage:
MPI-16/8: 125 mJ max, per tank cap
MPI-32:
180 mJ max, per tank cap

Output Electrical Specifications:
MPI-8: Single tank capacitor
MPI-16:
Dual, alternately fired tank capacitors
MPI-32:
Quad, alternately fired pairs of tank capacitors
Ignition Outputs are High-side firing referenced to the “T” pin on the output harness. Note: These outputs are not ground referenced unless the “T” lead is grounded. Recommend careful adherence to installation instructions.

Maximum Output Current Pulse Rating: 40 Amps
Note: Current pulse amplitude is dependent on the coils in use and the tank cap voltage.
IT-230 Series coils:
7 Amp pulse @ 230Volts
IT-150 Series coils:
35 Amps @ 150 Volts
IT-250 series coils:
20 Amps @ 250 Volts

4/20 mA Inputs:
4/20mA A: This input retards timing (if programmed) when schedule A is active.
4/20mA B:
This input retards the timing (if programmed) when schedule B is active.

Communications:
MPI-8/16: An auxilliary comm port is available, RS-485 interface, Modbus protocol
Note: This port has a user programmable slave ID, runs at 9600 baud. All parameters available and can be modified in parallel with main front panel display.

Note:
MPI Controllers have multiple inputs/outputs for all operating parameters. Please consult the Operating Manual for each MPI unit.

 

LITERATURE

For more information about this product, you can download the related literature here:

Sales Bulletin (MPI-04109B)

MPI-8/16 Installation Manual (MPI-04153A)


MPI-32 Installation Manual (MPI-04148A)